373 research outputs found

    A STUDY OF POTASSIUM ABSORPTION BY BARLEY ROOTS

    Full text link

    Association between serum ferritin and mortality : findings from the USA, Japan and European Dialysis Outcomes and Practice Patterns Study

    Get PDF
    Background: The Kidney Disease: Improving Global Outcomes guidelines have cautioned against administering intravenous (IV) iron to hemodialysis patients with high serum ferritin levels due to safety concerns, but prior research has shown that the association between high ferritin and mortality could be attributed to confounding by malnutrition and inflammation. Our goal was to better understand the ferritin-mortality association and relative influence of IV iron and inflammation in the USA, where ferritin levels have recently increased dramatically, and in Europe and Japan, where ferritin levels are lower and anemia management practices differ. Methods: Data from 18 261 patients in Phases 4 and 5 (2009-15) of the international Dialysis Outcomes and Practice Patterns Study, a prospective cohort study, were analyzed. Using Cox regression, we modeled the association between baseline ferritin and 1-year mortality with restricted cubic splines and assessed the impact of potential confounders. Results: Median ferritin levels were 718 ng/mL in the USA, 405 in Europe and 83 in Japan. High ferritin levels were associated with elevated mortality (relative to region-specific medians) in all three regions. The strength of this association was attenuated more by adjustment for malnutrition and inflammation than by IV iron and erythropoiesis-stimulating agent dose in each region. Conclusion: The utility of high ferritin as a biomarker for clinical risk due to excess iron stores may be limited, although caution regarding IV iron dosing to higher upper ferritin targets remains warranted. Research to resolve biomarker criteria for iron dosing, and whether optimal anemia management strategies differ internationally, is still needed

    Low hemoglobin at hemodialysis initiation : an international study of anemia management and mortality in the early dialysis period

    Get PDF
    Background. Anemia at hemodialysis (HD) initiation is common. Correcting low hemoglobin (Hgb) before HD initiation may improve survival by avoiding potential harms of chronic anemia, high doses of erythropoiesis-stimulating agents (ESAs) and intravenous (IV) iron in the early HD period, and/or rapid Hgb rise. Methods. We included 4604 incident HD patients from 21 countries in the Dialysis Outcomes and Practice Patterns Study Phases 4-5 (2009-15). Because low Hgb at HD start may reflect comorbidity or ESA hyporesponse, we restricted our analysis to the 80% of patients who achieved Hgb >= 10 g/dL 91-120 days after HD start (Month 4). Results. About 53% of these patients had Hgb = 10 g/dL). Month 1 Hgb was associated with first-year HD mortality (adjusted hazard ratio for 1 g/dL higher Hgb was 0.89; 95% confidence interval: 0.81-0.97), despite minimal differences in Month 4 Hgb. Patients with lower Hgb in Month 1 received higher doses of ESA, but not IV iron, over the first 3 months of HD. Results were consistent when excluding catheter users or adjusting for IV iron and ESA dose over the first 3 months. Conclusions. Even among patients with Hgb >= 10 g/dL 3 months later, anemia at HD initiation was common and associated with elevated mortality. A more proactive approach to anemia management in advanced chronic kidney disease (CKD) may thus improve survival on HD, though long-term prospective studies of non-dialysis CKD patients are needed

    Mortality risk in patients on hemodiafiltration versus hemodialysis : a 'real-world' comparison from the DOPPS

    Get PDF
    Background. With its convective component, hemodiafiltration (HDF) provides better middle molecule clearance compared with hemodialysis (HD) and is postulated to improve survival. A previous analysis of Dialysis Outcomes and Practice Patterns Study (DOPPS) data in 1998-2001 found lower mortality rates for high replacement fluid volume HDF versus HD. Randomized controlled trials have not shown uniform survival advantage for HDF; in secondary (non-randomized) analyses, better outcomes were observed in patients receiving the highest convection volumes. Methods. In a 'real-world' setting, we analyzed patients on dialysis >90 days from seven European countries in DOPPS Phases 4 and 5 (2009-15). Adjusted Cox regression was used to study HDF (versus HD) and mortality, overall and by replacement fluid volume. Results. Among 8567 eligible patients, 2012 (23%) were on HDF, ranging from 42% in Sweden to 12% in Germany. Median follow-up was 1.5 years during which 1988 patients died. The adjusted mortality hazard ratio (95% confidence interval) was 1.14 (1.00-1.29) for any HDF versus HD and 1.08 (0.92-1.28) for HDF > 20 L replacement fluid volume versus HD. Similar results were found for cardiovascular and infection-related mortality. In an additional analysis aiming to avoid treatment-by-indication bias, we did not observe lower mortality rates in facilities usingmore HDF (versus HD). Conclusions. Our results do not support the notion that HDF provides superior patient survival. Further trials designed to test the effect of high-volume HDF (versus lower volume HDF versus HD) on clinical outcomes are needed to adequately inform clinical practices

    Does Vesta Have Moons?

    Get PDF
    Previous searches for moons around Vesta have found nothing to an upper limit of 22.5 magnitude, that corresponds to 44 +/- 4 m diameter assuming the same albedo as Vesta. The Dawn mission's approach phase has dedicated satellite search observations consisting of two mosaic sequences bracketing the first observations of a complete rotation of Vesta scheduled for early July, 2011. In addition, we use the approach optical navigation image sequences for initial satellite searches. We will report any findings from these observations, and upper limits of magnitude and size

    Stationary Black Holes: Uniqueness and Beyond

    Get PDF
    The spectrum of known black-hole solutions to the stationary Einstein equations has been steadily increasing, sometimes in unexpected ways. In particular, it has turned out that not all black-hole-equilibrium configurations are characterized by their mass, angular momentum and global charges. Moreover, the high degree of symmetry displayed by vacuum and electro-vacuum black-hole spacetimes ceases to exist in self-gravitating non-linear field theories. This text aims to review some developments in the subject and to discuss them in light of the uniqueness theorem for the Einstein-Maxwell system.Comment: Major update of the original version by Markus Heusler from 1998. Piotr T. Chru\'sciel and Jo\~ao Lopes Costa succeeded to this review's authorship. Significantly restructured and updated all sections; changes are too numerous to be usefully described here. The number of references increased from 186 to 32

    Minimal changes in health status questionnaires: distinction between minimally detectable change and minimally important change

    Get PDF
    Changes in scores on health status questionnaires are difficult to interpret. Several methods to determine minimally important changes (MICs) have been proposed which can broadly be divided in distribution-based and anchor-based methods. Comparisons of these methods have led to insight into essential differences between these approaches. Some authors have tried to come to a uniform measure for the MIC, such as 0.5 standard deviation and the value of one standard error of measurement (SEM). Others have emphasized the diversity of MIC values, depending on the type of anchor, the definition of minimal importance on the anchor, and characteristics of the disease under study. A closer look makes clear that some distribution-based methods have been merely focused on minimally detectable changes. For assessing minimally important changes, anchor-based methods are preferred, as they include a definition of what is minimally important. Acknowledging the distinction between minimally detectable and minimally important changes is useful, not only to avoid confusion among MIC methods, but also to gain information on two important benchmarks on the scale of a health status measurement instrument. Appreciating the distinction, it becomes possible to judge whether the minimally detectable change of a measurement instrument is sufficiently small to detect minimally important changes

    The generation of phase differences and frequency changes in a network model of inferior olive subthreshold oscillations

    Get PDF
    This is an open-access article, free of all copyright, and may be freely reproduced, distributed, transmitted, modified, built upon, or otherwise used by anyone for any lawful purpose. The work is made available under the Creative Commons CC0 public domain dedicationIt is commonly accepted that the Inferior Olive (IO) provides a timing signal to the cerebellum. Stable subthreshold oscillations in the IO can facilitate accurate timing by phase-locking spikes to the peaks of the oscillation. Several theoretical models accounting for the synchronized subthreshold oscillations have been proposed, however, two experimental observations remain an enigma. The first is the observation of frequent alterations in the frequency of the oscillations. The second is the observation of constant phase differences between simultaneously recorded neurons. In order to account for these two observations we constructed a canonical network model based on anatomical and physiological data from the IO. The constructed network is characterized by clustering of neurons with similar conductance densities, and by electrical coupling between neurons. Neurons inside a cluster are densely connected with weak strengths, while neurons belonging to different clusters are sparsely connected with stronger connections. We found that this type of network can robustly display stable subthreshold oscillations. The overall frequency of the network changes with the strength of the inter-cluster connections, and phase differences occur between neurons of different clusters. Moreover, the phase differences provide a mechanistic explanation for the experimentally observed propagating waves of activity in the IO. We conclude that the architecture of the network of electrically coupled neurons in combination with modulation of the inter-cluster coupling strengths can account for the experimentally observed frequency changes and the phase differences.Peer reviewedFinal Published versio

    Gravitational Waves From Known Pulsars: Results From The Initial Detector Era

    Get PDF
    We present the results of searches for gravitational waves from a large selection of pulsars using data from the most recent science runs (S6, VSR2 and VSR4) of the initial generation of interferometric gravitational wave detectors LIGO (Laser Interferometric Gravitational-wave Observatory) and Virgo. We do not see evidence for gravitational wave emission from any of the targeted sources but produce upper limits on the emission amplitude. We highlight the results from seven young pulsars with large spin-down luminosities. We reach within a factor of five of the canonical spin-down limit for all seven of these, whilst for the Crab and Vela pulsars we further surpass their spin-down limits. We present new or updated limits for 172 other pulsars (including both young and millisecond pulsars). Now that the detectors are undergoing major upgrades, and, for completeness, we bring together all of the most up-to-date results from all pulsars searched for during the operations of the first-generation LIGO, Virgo and GEO600 detectors. This gives a total of 195 pulsars including the most recent results described in this paper.United States National Science FoundationScience and Technology Facilities Council of the United KingdomMax-Planck-SocietyState of Niedersachsen/GermanyAustralian Research CouncilInternational Science Linkages program of the Commonwealth of AustraliaCouncil of Scientific and Industrial Research of IndiaIstituto Nazionale di Fisica Nucleare of ItalySpanish Ministerio de Economia y CompetitividadConselleria d'Economia Hisenda i Innovacio of the Govern de les Illes BalearsNetherlands Organisation for Scientific ResearchPolish Ministry of Science and Higher EducationFOCUS Programme of Foundation for Polish ScienceRoyal SocietyScottish Funding CouncilScottish Universities Physics AllianceNational Aeronautics and Space AdministrationOTKA of HungaryLyon Institute of Origins (LIO)National Research Foundation of KoreaIndustry CanadaProvince of Ontario through the Ministry of Economic Development and InnovationNational Science and Engineering Research Council CanadaCarnegie TrustLeverhulme TrustDavid and Lucile Packard FoundationResearch CorporationAlfred P. Sloan FoundationAstronom
    corecore